Aruba Central allows you to configure and enable the following Access Points alerts:
—Generates an alert when a new virtual controller is detected.
—Generates an alert when a virtual controller is disconnected. This alert is enabled by default and the alert severity is . In the field, enter the duration after which the alert must be generated. The default value is 10 minutes.
Instant AP is detected.
—Generates an alert when a newInstant AP is disconnected. In the field, enter the duration after which the alert must be generated. The default value is 15 minutes.
—Generates an alert when anInstant AP is detected. This alert is enabled by default and the alert severity is .
—Generates an alert when a rogue—Generates an alert when an infrastructure attack is detected.
—Generates an alert when a client attack is detected.
—Generates an alert when an uplink has changed.
—Generates an alert when the modem is unplugged.
—Generates an alert when the modem is plugged.
Instant AP CPUCentral Processing Unit. A CPU is an electronic circuitry in a computer for processing instructions. utilization exceeds the threshold value. In the field, enter the duration after which the alert must be generated. You can add additional rule(s) for this alert.
—Generates an alert when theInstant AP memory utilization exceeds the threshold value. In the field, enter the duration after which the alert must be generated. You can add additional rule(s) for this alert.
—Generates an alert when the—Generates an alert when the Access Point is supplied with lesser power than the required power.
Instant AP radio channel utilization exceeds the threshold value. In the field, enter the duration after which the alert must be generated. From the drop-down, select the spectrum bandBand refers to a specified range of frequencies of electromagnetic radiation.: or . You can add additional rule(s) for this alert.
—Generates an alert when thedBmDecibel-Milliwatts. dBm is a logarithmic measurement (integer) that is typically used in place of mW to represent receive-power level. AMP normalizes all signals to dBm, so that it is easy to evaluate performance between various vendors.) exceeds the threshold value. In the field, enter the duration after which the alert must be generated. From the drop-down, select the spectrum band: or . You can add additional rule(s) for this alert.
—Generates an alert when the Noise Floor (—Generates an alert when the number of connected clients to the VC exceeds the threshold value. In the field, enter the duration after which the alert must be generated. You can add additional rule(s) for this alert.
—Generates an alert when the number of connected clients to the AP exceeds the threshold value. User can enter the threshold value after which the alerts must be generated. The recommended value is 15 minutes and above. You can add additional rule(s) for this alert.
Instant AP or Campus APCampus APs are used in private networks where APs connect over private links (LAN, WLAN, WAN or MPLS) and terminate directly on controllers. Campus APs are deployed as part of the indoor campus solution in enterprise office buildings, warehouses, hospitals, universities, and so on. radio frames retry percent exceeds the threshold value. In the field, enter the duration after which the alert must be generated. From the drop-down, select the spectrum band: or . You can add additional rule(s) for this alert.
—Generates an alert when theInstant AP upgrade failure such as, no firmware image is available or there is no response from the device.
—Generates an alert when there is any