Aruba Central Online Help
You are here: Home > Monitoring & Reports > Alerts & Events > Switch Alerts

Switch Alerts

Aruba Central allows you to configure and enable the following switch alerts:

  • New Switch Connected—Generates an alert when a new switch is connected.
  • Switch Disconnected—Generates an alert when a switch is disconnected. This alert is enabled by default and the alert severity is Major. In the Duration field, enter the duration after which the alert must be generated. The default value is 10 minutes.
  • Switch Mismatch Config—Generates an alert when there is a mismatch in switch configuration.
  • Switch Hardware Failure—Generates an alert when the switch hardware fails. The following are the typical hardware failures for Aruba and MAS switches:

    Aruba switches

    MAS switches

    • Fan failure.
    • High temperature.
  • Switch NAE Status—Generates an alert when the NAE Status for the AOS-CX switches exceed the Normal value, based on the severity configured. This alert is disabled by default and the alert severity is Major. If you want to generate alerts for the NAE Status of value Disabled, then set the alert severity to Warning.

  • Switch CPU Utilization—Generates an alert when the switch CPUCentral Processing Unit. A CPU is an electronic circuitry in a computer for processing instructions. utilization exceeds the threshold value. In the Duration field, enter the duration after which the alert must be generated. You can add additional rule(s) for this alert.
  • Switch Memory Utilization—Generates an alert when the switch memory utilization exceeds the threshold value. In the Duration field, enter the duration after which the alert must be generated. You can add additional rule(s) for this alert.
  • Switch Port Tx Rate—In the Transform Function drop-down, select either absolute or percentage. Select absolute to generate an alert if the data transmission rate of the port (in terms of MbpsMegabits per second) exceeds the threshold value. Select percentage to generate an alert if the data transmission rate of the port (in terms of utilization as a percentage of total bandwidth available) exceeds the threshold value. In the Interface field, enter the interface name. You can add additional rule(s) for this alert.
  • Switch Port Rx Rate—In the Transform Function drop-down, select either absolute or percentage. Select absolute to generate an alert if the data reception rate of the port (in terms of Mbps) exceeds the threshold value. Select percentage to generate an alert if the data reception rate of the port (in terms of utilization as a percentage of total bandwidth available) exceeds the threshold value. In the Interface field, enter the interface name. You can add additional rule(s) for this alert.
  • Switch Port Input Errors—Generates an alert when the percentage of input errors on the port exceeds the threshold value. In the Interface field, enter the interface name. You can add additional rule(s) for this alert.
  • Switch Port Output Errors—Generates an alert when the percentage of output errors on the port exceeds the threshold value. In the Interface field, enter the interface name. You can add additional rule(s) for this alert.
  • Switch Port Duplex Mode—Generates an alert when the port is operating in half-duplex mode. In the Interface field, enter the interface name.
  • Switch PoE Utilization—Generates an alert when the PoE utilization for a port exceeds the critical and major threshold value. This alert is enabled by default and the alert severity is Critical. You can add additional rule(s) for this alert.
  • Switch STP Root Change—Generates an alert when a switch configured as the Spanning Tree Protocol (STPSpanning Tree Protocol. STP is a network protocol that builds a logical loop-free topology for Ethernet networks.) root is replaced by another switch in the LANLocal Area Network. A LAN is a network of connected devices within a distinct geographic area such as an office or a commercial establishment and share a common communications line or wireless link to a server.. This alert is enabled by default and the alert severity is Major.
  • Stack Member Added/Removed—Generates an alert when a stack member is added or removed. This alert is enabled by default and the alert severity is Major.
  • Switch Stack Commander Change—Generates an alert when there is a change in Stack commander. This alert is enabled by default and the alert severity is Major.
  • Switch Uplink Port Usage—Generates an alert when the total uplink port usage of a switch at a site exceeds the configured value in gigabytes (GB) within a specified duration. The severity for this alert is Warning. In the exceeds (in GB) field, enter the uplink port usage value in GB. In the Duration field, enter the duration after which the alert occurs. The alert must be generated if the condition persists even after this duration.